Outdoor cable terminations for single-core screened polymer insulated cables with copper wire screen

Outdoor cable terminations for single-core screened polymer insulated cables with copper wire screen


Application: designed for termination cables of type: N(A)2XS(2)Y, N(A)2XS(F)(L)(2)Y, YH(A)KXS, XUH(A)KXS, XH(A)KXS, X(RU)H(A)KXS.

The construction of the outdoor termination is similar to indoor termination.
Additionally depending on the voltage level heat shrink sheds are shrinked on insulation tube.
They prevent from creeping current.

Properties of the terminations

  • resistant to hard environmental conditions,
  • for cables with cross-sections up to 400 mm2 (concerns terminations with screw lugs) ,
  • in case of terminations with screw terminals they limit the number of tools necessary for the assembling,
  • heat shrink tubes applied in the termination create insulation protection against superficial discharges,
  • resistant to UV radiation,
  • full protection against moisture penetration,
  • high electrical and mechanical resistance,
  • short assembling time thanks to simple construction and attached installation guide,

Positive technical approving issued by Institute of Power Engineering in conformity with requirements of norms PN-90/E-06401 i PN-HD 629.1 S2:2006.
 

Voltage range

Cable cross-section [mm2]

Type of cable termination

Length [mm]

Index

6/10kV

50-95

THP-N-10-CXd1 50-95 (S)

450

WGENCD1IK00S1

 

120-240

THP-N-10-CXd1 120-240 (S)

450

WGENCD1LO00S1

 

240-400

THP-N-10-CXd1 240-400 (S)

450

WGENCD1OR00S1

8,7/15kV

35-95

THP-N-15-CXd1 35-95 (S)

450

WGENDD1HK00S1

 

95-240

THP-N-15-CXd1 95-240 (S)

450

WGENDD1KO00S1

 

185-400

THP-N-15-CXd1 185-400 (S)

450

WGENDD1NR00S1

12/20kV

50-150

THP-N-20-CXd1 50-150 (S)

450

WGENED1HM00S1

 

95-240

THP-N-20-CXd1 95-240 (S)

450

WGENED1JO00S1

 

185-400

THP-N-20-CXd1 185-400 (S)

450

WGENED1NR00S1

Termination sets enable making of three single-phase terminations, supplied with screw lugs.
 

Voltage range

Cable cross-section [mm2]

Type of cable termination

Length [mm]

Index

6/10kV

35-95

THP-N-10-CXd1 35-95

450

WGENCD1HK0001

 

95-240

THP-N-10-CXd1 95-240

450

WGENCD1KO0001

8,7/15kV

35-95

THP-N-15-CXd1 35-95

450

WGENDD1HK0001

 

95-240

THP-N-15-CXd1 95-240

450

WGENDD1KO0001

12/20kV

35-95

THP-N-20-CXd1 35-95

450

WGENED1HK0001

 

70-240

THP-N-20-CXd1 70-240

450

WGENED1JO0001

Termination sets enable making of three single-phase terminations They are meant for termination cables with the use of compression terminals, sets don’t contain terminals. Meant for leakproof cable lugs.